6.3 JOG Speeds and Reduced Speeds P31<br />

6 - 8 en-938818/7<br />

Category Servo-control<br />

Type 4 Unsigned decimal<br />

No. of words 5<br />

Description<br />

Used to define the speeds corresponding to <strong>manual</strong> mode and the reduced speeds requested by the machine<br />

processor.<br />

Principle<br />

Words N0 to N2<br />

Words N0 to N2 define the speeds of movement on the axes:<br />

- slow JOG for N0,<br />

- normal JOG for N1,<br />

- fast JOG for N2.<br />

The speeds are expressed in mm/min.<br />

They can be overridden by the feed rate potentiometer.<br />

The normal and fast speeds are accessible from the machine panel.<br />

Words N3 and N4<br />

Words N3 and N4 are used to set the <strong>parameter</strong>s of the reduced speeds requested by the PLC function<br />

(VREDUCT = 1).<br />

Word N3 gives the reduced speed on linear axes in mm/min.<br />

Word N4 gives the reduced speed on rotary axes in deg/min.