P30 P31 P32 P20 P21 P56 P22 P23 P57 P55 P24 P52 P19 P33 P53 P66<br />

6.19 Setting the Maximum Speeds and Accelerations<br />

Actions<br />

Apply the following equation and record the computed values in<br />

the table.<br />

DDM = VITMAX / TV<br />

Where:<br />

VITMAX: Maximum speed on the axis (in mm/min or deg/min).<br />

REMARK: VITMAX (in mm/min) is equivalent to VMAX (in mm/s).<br />

TV : Speed buildup time (from 0 to VMAX) (in ms).<br />

DDM : Maximum acceleration (in mm/s2 or deg/s2 ).<br />

Servo-Control<br />

Axis @ VITMAX (in mm/min or deg/min) TV (in ms) DDM (in mm/s2 or deg/s2 0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

)<br />

Enter the values of VITMAX in the words of P30 (the values can<br />

also be recorded in the table of Section 3.3).<br />

Enter the values of DDM in the words of P32 (the values can also<br />

be recorded in the table of Section 3.3).<br />

! CAUTION<br />

A value other than zero must be entered in P32 for each axis declared in P2.<br />

en-938818/7 6 - 43<br />