13.2.4 Unloading a Parameter Table<br />

The <strong>parameter</strong> table can be unloaded to a PC via the RS232 link using the NUM software (APA10, NUMPC, PLCTOOL<br />

or SETTOOL).<br />

Requirements<br />

«MACHINE SETUP DATA» menu displayed.<br />

Load peripheral on and connected to one of the serial lines of the CPU.<br />

Serial line compatible with the peripheral selected (see Operator Manual).<br />

Actions<br />

Set the peripheral to load mode.<br />

#<br />

Select «PERIPHERAL UNLOAD». ☞ 3<br />

The cursor moves to line 3 and the message «READY?» is displayed on the dialogue line.<br />

Enter ☞ Y<br />

The <strong>CN</strong>C job reference (%nnnnnnnn) is displayed on the dialogue line.<br />

You may enter a comment after the job reference.<br />

You can also edit the job reference.<br />

Start the unload procedure on the <strong>CN</strong>C side.<br />

Start the load procedure on the peripheral side. ☞<br />

The <strong>parameter</strong> table is unloaded with a return to the «MACHINE SETUP DATA» menu at the end of the operation.<br />