29.07.2013 Views

Operator Terminal System Manual - 11276916.pdf

Operator Terminal System Manual - 11276916.pdf

Operator Terminal System Manual - 11276916.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>System</strong> <strong>Manual</strong> – DOP11A <strong>Operator</strong> <strong>Terminal</strong>s<br />

Programming<br />

Programming with the programming software<br />

[Setup] menu The [Setup] menu includes functions for configuring the terminal.<br />

10433AEN<br />

<strong>System</strong> signals With this option you can define handshake signals between terminal and controller.<br />

Current display register<br />

Data register in the controller that contains the number of the block (in run mode) to be<br />

displayed on the screen. The data register is automatically updated when the block is<br />

changed. This register does not affect block selection.<br />

New display register<br />

Data register in the controller that defines which block will be displayed on the screen.<br />

Buzzer register<br />

Not applicable for DOP11A-10.<br />

The value of this register defines the buzzer tone. Tones and scales are given in the<br />

table below. Value 0 means there is no tone. All values in the table are given in Hz.<br />

C D E F G A H<br />

Contra 33 37 41 44 49 55 62<br />

Large 65 73 82 87 98 110 123<br />

Small 131 147 165 175 196 220 247<br />

One 262 294 330 349 392 440 494<br />

Two 523 587 659 698 784 880 988<br />

Three 1046 1174 1318 1397 1568 1760 1975<br />

Four 2093 2348 2636 2794 3136 3520 3950<br />

Five 4186<br />

I<br />

0<br />

7<br />

103