<strong>System</strong> <strong>Manual</strong> – DOP11A <strong>Operator</strong> <strong>Terminal</strong>s<br />

Programming<br />

Communication with MOVIDRIVE® and MOVITRAC® 07<br />

Indexed communication with inverters connected via RS-485<br />

In addition to directly specifying the RS-485 address, communication can also be<br />

performed via index. This means the RS-485 address is stored in a variable of the<br />

operator terminal and can be set by the operator.<br />

Example<br />

A project is created in which the operator can enter the RS-485 address of the inverter.<br />

This has the advantage that the actual address of the inverter must not be known when<br />

creating the DOP project. The operator can enter and specify the address during system<br />

operation.<br />

The actual speed of a drive is to be read via index. The actual speed is displayed in<br />

parameter P000.<br />

1. Define the register R1 to which the RS-485 address of the inverter to be addressed<br />

will be stored in the HMI-Builder under [View] / [Name list] and define Parameter<br />

P000 as symbolic name for the actual speed:<br />

10784AEN<br />

I<br />

0<br />

7<br />

65