I<br />

Unit Functions<br />

8 Alarm handling<br />

0<br />

8.2 Alarm handling<br />

This chapter is not applicable to DOP11A-10.<br />

The [alarm handling] function alerts the operator to incidents in the process that require<br />

immediate action.<br />

Alarm grouping Alarms can be divided into several groups in the terminal depending on the teminal type<br />

in use.<br />

You can assign different color attributes to each group (DOP11A-30 to DOP11A-50).<br />

Alarms can be sorted by groups in the alarm block. Alarm groups need not be defined.<br />

Defining alarm<br />

groups<br />

Function Description<br />

Alarm groups Alarms can be divided into groups, for example to catgorize them according to their<br />

severity levels.<br />

Alarm message This function defines which signal will trigger an alarm and which text will be<br />

displayed when the signal is activated.<br />

Alarm list Lists alarms that occurred during operation.<br />

Text-based printouts are not supported when using Unicode.<br />

<strong>Terminal</strong> Number of alarm groups<br />

DOP11A-20 4<br />

DOP11A-30 3 ... 5 (depending on the selected font size)<br />

DOP11A-40 16<br />

DOP11A-50 7 ... 11 (depending on the selected font size)<br />

You define alarm groups [Functions] / [Alarm groups]. The properties of the alarm group<br />

are defined in following dialog.<br />

Parameter Description<br />

Group name User defined name for the alarm group<br />

Summary notify Active Digital signal that is output by the terminal when the print<br />

process has been completed.<br />

Unacknowledged Digital signal that is activated if alarms in the group have<br />

not been acknowledged.<br />

Remote acknowl- Digital signal that, if enabled, acknowledges all alarms in<br />

edge<br />

the group at the same time.<br />

Colors Define the colors for active, acknowledged and inactive alarms as well as for<br />

alarms in normal state. For DOP11A-30 to DOP11A-50 only.<br />

184 <strong>System</strong> <strong>Manual</strong> – DOP11A <strong>Operator</strong> <strong>Terminal</strong>s