I<br />

Unit Functions<br />

8 Message library<br />

0<br />

8 Unit Functions<br />

8.1 Message library<br />

The [Message library] function enables you to create text tables where values between<br />

0 and 65535 are linked with texts. The [Message library] function is used among others<br />

to display each sequence in a sequence control. The function can also be used to<br />

display error codes. An analog signal creates error codes that are linked with texts in a<br />

text block. The function is also used for assigning specific values to analog signals<br />

depending on the selected text.<br />

The message library consists of one or several text tables with up to 512 text character<br />

strings. Each text string can have up to 40 characters. Activate this option under [Functions]<br />

/ [Message library].<br />

Parameter Description<br />

Library Specify a number for the message library.<br />

Name Define a name for the message library.<br />

You can edit a message library by selecting the library and clicking [Edit]. Several edit<br />

windows can be opened at the same time.<br />

Parameter Description<br />

Text no. Enter a number for the text (0 - 65535).<br />

Text Any text that is called once the current signal shows the text<br />

number for the text.<br />

Example<br />

Below a simple example to explain the function. Each sequence step in our sequence<br />

control is displayed by a text.<br />

D0=0<br />

D0=1<br />

D0=2<br />

D0=3<br />

54131AXX<br />

[1] The object is placed onto the conveyor belt.<br />

[2] Mount tool X<br />

[3] Mount tool Y<br />

[4] Remove object from the conveyor belt<br />

[1]<br />

[2]<br />

[3]<br />

[4]<br />