Network Functions and Communication<br />

9 Network communication<br />

Request / provide<br />

local address<br />

The local IP address is requested and provided. Should be set to 0.0.0.0 if the IP<br />

address is to be provided by the remote node. The parameter is only used with PPP<br />

connections.<br />

If the terminal acts as server or as server and client, and you change the addresses<br />

under [Request / provide local address], the new addresses will be saved. If the terminal<br />

acts as client, the addresses are set to 0.0.0.0. If you change the terminal status to<br />

server or server and client, the stored addresses will be used.<br />

Node 1<br />

Remote<br />

192.168.1.2<br />

Local<br />

192.168.1.1<br />

54418AEN<br />

Modem You will have to configure the parameters in the [Modem] window if you want to establish<br />

a connection using the modem. A special cable is required for this purpose.<br />

[Setup] / [Peripherals]<br />

54425AEN<br />

Select [Setup] / [Peripherals] from the menu.<br />

Select the TCP/IP connection on the serial port and click on [Edit].<br />

Next, click the [Modem] button.<br />

236 <strong>System</strong> <strong>Manual</strong> – DOP11A <strong>Operator</strong> <strong>Terminal</strong>s<br />

Node 2<br />

Remote<br />

0.0.0.0<br />

Local<br />

0.0.0.0<br />

9-pin socket 25-pin plug<br />

Shield<br />

2 2<br />

3 3<br />

5 7<br />

7 8<br />

8 4<br />

6<br />

20<br />

Shield