20.05.2014 Views

Forthbank Wind Energy Development - Partnerships for Renewables

Forthbank Wind Energy Development - Partnerships for Renewables

Forthbank Wind Energy Development - Partnerships for Renewables

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Forthbank</strong> <strong>Wind</strong> <strong>Energy</strong> <strong>Development</strong><br />

taken into account and all the properties have been assessed as having windows in each of<br />

the facades as a worst case scenario.<br />

14.3.3 The properties identified within a distance of 900 metres and 130 degrees either side of the<br />

north of the proposed wind turbine locations were analysed to select a short list of receptors<br />

which are orientated towards the turbine. Properties were chosen based on their proximity to<br />

the proposed wind turbine locations and having either open space or wider roads adjacent to<br />

them, allowing open view towards the turbine location. Properties were also chosen to<br />

illustrate shadow flicker effects over the short, medium and long range views.<br />

14.3.4 The location of the assessed receptor properties are shown in Figure 14.1 and detailed in<br />

Table 14.1 below.<br />

Park Farm (H1)<br />

14.3.5 According to the OS Map and from observations made during a site visit there is one<br />

residential building and farm buildings located at Park Farm to the southeast of the proposed<br />

turbine locations. All of the façades, apart from the most easterly façade, face the proposed<br />

turbine locations.<br />

14.3.6 The property has been modelled as having three façades as detailed below:<br />

• North façade, orientated at 20° relative to north and measuring as standard, 10m<br />

wide and 5m high;<br />

• South façade, orientated at 200° relative to north and measuring, as standard, 10m<br />

wide and 5m high; and<br />

• West façade, orientated at 290° relative to north and measuring, as standard, 10m<br />

wide and 5m high.<br />

41-51, Bowhouse Gardens (H2)<br />

14.3.7 According to the OS Map and from observations made during a site visit there is a block of<br />

flats located to the northwest of the proposed turbine 1 location. All of the façades, apart from<br />

the most northerly façade, face the proposed turbine locations.<br />

14.3.8 The property has been modelled as having three façades as detailed below:<br />

• East façade, orientated at 90° relative to north and measuring as standard, 10m<br />

wide and 5m high;<br />

• South façade, orientated at 180° relative to north and measuring, as standard, 10m<br />

wide and 5m high; and<br />

• West façade, orientated at 270° relative to north and measuring, as standard, 10m<br />

wide and 5m high.<br />

November 2010 Chapter 14 Page 6<br />

Copyright <strong>Partnerships</strong> <strong>for</strong> <strong>Renewables</strong> <strong>Development</strong> Co. Ltd 2010 ©

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!