4. An emergency overflow path shall be provided on the plans for sag locations. An emergency<br />

overflow path is the path the storm water will take if the drainage facility becomes clogged or<br />

ceases to function as designed. The emergency overflow path must be located within public<br />

right-<strong>of</strong>-way or within a drainage easement.<br />

5. Curb inlet depth shall not be less than 4.5’ from top <strong>of</strong> curb for all public improvements.<br />

6. Inlets are required at the low point <strong>of</strong> a superelevation to prevent flow across the roadway.<br />

7. Multiple sag inlets shall be located no closer than 300’.<br />

Section 4 – Drainage Design Requirements May 2012 Page 4-14