E. The service enclosure shall be manufactured in a UL listed shop. It shall have a continuous<br />

piano hinge with stainless steel pin along the side. An enclosure with the hinge along the top<br />

<strong>of</strong> the box will not be acceptable. Service enclosures shall have no more than two (2) pieces<br />

<strong>of</strong> dead front trim. All conduits entering the service enclosure shall be through the bottom <strong>of</strong><br />

the services enclosure.<br />

F. For traffic signal installations with luminaries and illuminated street name signs (ILSN),<br />

separate photocell and lighting contactor will be required for luminaries and ILSN (Total two<br />

photocells and two lighting contactor).<br />

G. Install in line fuses at all service connections.<br />

PART 4 - MEASUREMENT AND PAYMENT<br />

4.01 MEASUREMENT<br />

A. This Item shall be measured on a per Each (EA) electrical service installed or removed.<br />

4.02 PAYMENT<br />

A. All work performed and materials furnished in accordance with this Item will be paid for at<br />

the unit bid price for as provided under measurement for “Electrical Service” in accordance<br />

with TxDOT Item 628. This price is full compensation for all material, labor, equipment,<br />

tools and superintendence necessary to complete the work.<br />

END OF SECTION<br />

<strong>City</strong> <strong>of</strong> <strong>Frisco</strong> May 2012<br />

Standard Technical Specification Electrical Service 260501-2