SECTION 330523<br />

TRENCHLESS UTILITY INSTALLATION<br />

PART 1 – GENERAL<br />

1.01 DESCRIPTION<br />

A. All material, labor, equipment, tools and superintendence necessary to furnish and install<br />

utility lines using trenchless installation methods in accordance with Public Works<br />

Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Item 503.<br />

1.02 REFERENCES<br />

A. Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Item 503<br />

B. <strong>City</strong> <strong>of</strong> <strong>Frisco</strong>’s Standard Details included in the plans.<br />

1.03 QUALITY ASSURANCE<br />

A. DESIGN CRITERIA<br />

The pipe casing (or carrier pipe on uncased bores) shall be designed by a Licensed<br />

Pr<strong>of</strong>essional Engineer for the following loading conditions and applicable combinations<br />

there<strong>of</strong>:<br />

1. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable<br />

2. Earth loading with the height <strong>of</strong> fill above the casing as shown on the plans<br />

3. Loads applied during jacking, including axial load from jacking<br />

4. All other applicable loading conditions, including loads applied during transportation and<br />

handling.<br />

B. INSTALLER'S QUALIFICATIONS<br />

Installation shall be by a competent, experienced contractor or sub-contractor. The<br />

installation contractor shall have a satisfactory experience record <strong>of</strong> at least three (3) years<br />

engaged in similar work <strong>of</strong> equal scope.<br />

All welding shall be performed by a certified welder in the state <strong>of</strong> Texas.<br />

C. PERFORMANCE REQUIREMENTS<br />

1.04 SUBMITTALS<br />

Lateral or vertical variation in the final position <strong>of</strong> the pipe casing (or carrier pipe on<br />

uncased bores) from the line and grade established by the ENGINEER shall be permitted<br />

only to the extent <strong>of</strong> 1" in 10' feet, provided that such variation shall be regular and only in<br />

the direction that will not detrimentally affect the function <strong>of</strong> the carrier pipe.<br />

Submittals shall include:<br />

<strong>City</strong> <strong>of</strong> <strong>Frisco</strong> May 2012<br />

Standard Technical Specification Trenchless Utility Installation 330523-1