SECTION 331213<br />

WATER SERVICE CONNECTIONS<br />

PART 1 – GENERAL<br />

1.01 DESCRIPTION<br />

A. All material, labor, equipment, tools and superintendence necessary to furnish and install<br />

Water Service Connections in accordance with Public Works Construction <strong>Standards</strong>,<br />

NCTCOG, 4 th Edition, Item 502.10.<br />

1.02 REFERENCES<br />

A. AWWA C800, AWWA Standard for Underground Service Line Valves and Fittings<br />

B. AWWA C901, Polyethylene Pressure Pipe and Tubing, 1 in. Through 3 in. for Water Service,<br />

Latest Revision.<br />

C. Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Item 502.10<br />

D. <strong>City</strong> <strong>of</strong> <strong>Frisco</strong> Standard Detail for Typical Service Connection.<br />

PART 2 – PRODUCTS<br />

A. Refer to Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Items 501.10 and<br />

501.21.<br />

B. Water service pipe shall be polyethylene tubing with detectable tracing wire.<br />

C. Tracing wire shall be 10 AWG Standard with HDPE coating.<br />

D. Tape for the tracing wire shall be polypropylene.<br />

E. Service couplings, meter valves and corporation stops shall be “no-lead brass” fittings.<br />

PART 3 – EXECUTION<br />

3.01 PREPARATION<br />

A. Refer to Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Item 502.10.3.<br />

B. Tracer wire shall be attached to the polyethylene tubing with two independent, continuous,<br />

spiral-wound polypropylene tape layers.<br />

C. Bullhead services that branch at the end <strong>of</strong> a service line to serve two or more customers will<br />

not be allowed.<br />

3.02 CONSTRUCTION<br />

A. Service taps shall be made after the mains have been laid.<br />

<strong>City</strong> <strong>of</strong> <strong>Frisco</strong> May 2012<br />

Standard Technical Specification Water Service Connections 331213-1