SECTION 024100<br />

GENERAL SITE PREPARATION<br />

PART 1 - GENERAL<br />

1.01 DESCRIPTION<br />

A. All materials, labor, equipment, tools and superintendence necessary for the preparation <strong>of</strong><br />

the project site not covered elsewhere in accordance with Public Works Construction<br />

<strong>Standards</strong>, NCTCOG, 4 th Edition, Item 203.<br />

B. This Section also includes:<br />

1.01 REFERENCES<br />

1. Protecting existing vegetation to remain.<br />

2. Removing existing vegetation.<br />

3. Clearing and grubbing<br />

4. Demolition<br />

5. Removal <strong>of</strong> all items within the limits <strong>of</strong> construction not specifically noted to remain.<br />

A. Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Items 203.1, 203.2, and 203.3<br />

1.02 PROJECT CONDITIONS<br />

A. Traffic: Minimize interference with adjoining roads, streets, walks, and other adjacent<br />

occupied or used facilities during site-clearing operations.<br />

1. Do not close or obstruct streets, walks, or other adjacent occupied or used facilities<br />

without permission from <strong>City</strong> and authorities having jurisdiction.<br />

2. Provide alternate routes around closed or obstructed traffic ways if required by Owner<br />

or authorities having jurisdiction.<br />

B. Salvaged materials: Carefully remove items indicated to be salvaged and store as directed<br />

by the <strong>City</strong>.<br />

C. Utility Locator Service: Notify utility locator service for area where Project is located<br />

before site clearing.<br />

1. Call DigTESS at 1-800-344-8377<br />

2. Contact <strong>City</strong>’s ROW Division <strong>of</strong> Public Works at 972-292-5820 for locates<br />

D. Do not commence site clearing operations until temporary erosion and sedimentation control<br />

measures are in place.<br />

<strong>City</strong> <strong>of</strong> <strong>Frisco</strong> May 2012<br />

Standard Technical Specification General Site Preparation 024100-1