PART 1 – GENERAL<br />

1.01 DESCRIPTION<br />

SECTION 333130<br />

CENTRIFUGALLY CAST FIBERGLASS REINFORCED PIPE<br />

FOR GRAVITY WASTEWATER MAINS<br />

A. All material, labor, equipment, tools and superintendence necessary to furnish and install<br />

Centrifugally Cast Fiberglass Reinforced Pipe For Gravity Wastewater Mains in accordance<br />

with Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Items 501.24, 505 and<br />

507.<br />

1.02 REFERENCES<br />

A. ASTM D3262 Standard Specification for “Fiberglass” (Glass-Fiber-Reinforced<br />

Thermosetting Resin) Sewer Pipe, Latest Revision<br />

B. ASTM D4161 Standard Specification for “Fiberglass” (Glass-Fiber-Reinforced<br />

Thermosetting-Resin) Pipe Joints Using Flexible Elastomeric Seals, Latest Revision<br />

C. ASTM D3840 Standard Specification for “Fiberglass” (Glass-Fiber-Reinforced<br />

Thermosetting-Resin) Pipe Fittings for Nonpressure Applications<br />

D. Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Items 501.24, 505 and 507<br />

PART 2 – PRODUCTS<br />

2.01 MATERIALS<br />

A. Refer to Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Item 501.24.<br />

PART 3 – EXECUTION<br />

3.01 CONSTRUCTION<br />

A. Refer to Public Works Construction <strong>Standards</strong>, NCTCOG, 4 th Edition, Items 505 and 507.<br />

B. The construction <strong>of</strong> all wastewater mains shall begin at the outlet or lower end, unless<br />

otherwise directed by the Inspector.<br />

C. Appurtenances shall be constructed as soon as the wastewater main <strong>of</strong> which they are a part<br />

is constructed to their locations. Upon request by the Contractor, the Inspector may permit<br />

postponement <strong>of</strong> the construction <strong>of</strong> manholes on wastewater mains, and the Contractor<br />

shall, without additional cost to the Owner, lay the pipe continuously through the manhole<br />

location.<br />

D. The construction <strong>of</strong> appurtenances in advance <strong>of</strong> construction <strong>of</strong> the wastewater line will not<br />

be permitted.<br />