SECTION 334113<br />

REINFORCED CONCRETE PIPE<br />

PART 1 - GENERAL<br />

1.01 DESCRIPTION<br />

A. All material, labor, equipment, tools and superintendence necessary to furnish and install<br />

Reinforced Concrete Pipe in accordance Texas Department <strong>of</strong> Transportation Standard<br />

Specifications for Construction and Maintenance <strong>of</strong> Highways, Streets, and Bridges Item<br />

464.<br />

1.02 REFERENCES<br />

A. TxDOT Items 400, 402, 403, 420, 464, 467, and 473<br />

B. Section 330510 Trenching, Backfilling and Comaction<br />

C. <strong>City</strong> <strong>of</strong> <strong>Frisco</strong>’s Standard Detail for Storm Drain Embedment and Backfill.<br />

D. TxDOT standard details included in the plans.<br />

PART 2 - PRODUCTS<br />

2.01 MATERIALS<br />

A. Refer to TxDOT Item 464.2.<br />

PART 3 - EXECUTION<br />

3.01 PREPARATION<br />

A. Refer to TxDOT Item 464.3. The Excavation, Shaping, Bedding, and Backfill section<br />

references TxDOT Item 400. The <strong>City</strong> <strong>of</strong> <strong>Frisco</strong>’s Standard Detail for Standard Storm Drain<br />

Embedment and Backfill detail shall replace Figure 1 in TxDOT Item 400.<br />

B. After compaction and subgrade preparation but prior to paving, television inspections tests<br />

are required on all storm sewer mains laterals and culverts as identified on the construction<br />

plans. The minimum information to be provided to the Owner and <strong>City</strong>’s inspectors, in both<br />

text and video form, are line designation, length, slope, and joints. Acceptable video formats<br />

are VHS and DVD. Any line or lines found to be defective will be corrected and another<br />

television inspection shall be performed at the contractor’s expense<br />

PART 4 - MEASUREMENT AND PAYMENT<br />

4.01 MEASUREMENT<br />

A. Refer to TxDOT 464.4.<br />

<strong>City</strong> <strong>of</strong> <strong>Frisco</strong> May 2012<br />

Standard Technical Specification Reinforced Concrete Pipe 334113-1