27.12.2014 Views

TVG-Series System Guide v1-4 - SerVision

TVG-Series System Guide v1-4 - SerVision

TVG-Series System Guide v1-4 - SerVision

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SerVision</strong><br />

<strong>TVG</strong> <strong>System</strong> <strong>Guide</strong><br />

To set advanced recorder settings for a camera:<br />

1. In the bottom of the Camera configuration screen, under Recorder, select Enable Advanced Settings.<br />

The fields required to configure advanced settings are displayed along with the other recorder settings above<br />

the checkbox:<br />

Figure 107: A dv anced recorder settings<br />

2. To modify the disk allocation for this recording stream, under Size on Disk, specify the proportion of the<br />

disk space to allocate for the stream, as a percent value.<br />

The percentage that is already allocated for the other cameras is indicated above the field – for example, “33%<br />

in use by other recorders.” You can choose to allocate as much of the remaining disk space to this recorder as<br />

you wish. For example, if 33% of the total available disk space is already allocated to the other recorders, you<br />

could choose to allocate an additional 60% to this recorder. This would mean that 93% of the disk space is<br />

allocated to all the recorders together. The sum of the Size on Disk values of all the recorders cannot exceed<br />

98.<br />

Note: To modify the allocation of the other recorders, navigate to the Camera configuration screen of each<br />

recorder and modify the value in the Size on Disk field there.<br />

Note: To reset all disk allocations to their default values, in the Camera Summary screen, click Set<br />

Recording Disk Size to Default.<br />

3. If you want to record linearly, select Write Protect. The Warn When ____% Full field is added to the<br />

screen. .<br />

Figure 108: W arn W hen ____% Full field<br />

If Write Protect is selected, recording continues until all the allocated disk space is full. To restart<br />

recording, you must manually erase the existing recordings (see Erasing Recorded Video, page 104).<br />

If Write Protect is not selected, recording follows the FIFO model: when the disk allocation is full, the<br />

earliest recordings from this camera are erased to make room for new recordings. Skip to step 5.<br />

4. In the Warn When ____% Full field, specify whether you want the <strong>TVG</strong> to send warning messages via e-<br />

mail about the availability of storage space, as follows:<br />

Value<br />

Description<br />

0 No warning messages are sent.<br />

Configuring Camera Settings 100

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!