27.12.2014 Views

TVG-Series System Guide v1-4 - SerVision

TVG-Series System Guide v1-4 - SerVision

TVG-Series System Guide v1-4 - SerVision

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SerVision</strong><br />

<strong>TVG</strong> <strong>System</strong> <strong>Guide</strong><br />

Field<br />

Presets<br />

(Sensors only)<br />

Description<br />

All PTZ cameras connected to the <strong>TVG</strong> that support presets are listed below this<br />

heading. If you want one of these cameras to automatically aim at a preset location<br />

when a sensor event begins, beside the name of the camera, select the number of the<br />

preset location.<br />

Note: Preset locations are defined and assigned numbers using a client application such<br />

as the MultiClient. For additional information, please refer to the relevant client<br />

application guide.<br />

5. Under Notifications, under When Sensor Off or On Activator Deactivated, specify the actions that<br />

should be performed when an event ends, as described above.<br />

6. Click Update, and then save the settings. They will be implemented after the unit is restarted (see Saving<br />

Configuration Changes, page 125).<br />

Configuring Sensor 1 to Switch Outlines<br />

A toggle switch can be connected to the In1 connector on the <strong>TVG</strong> instead of a sensor. The switch can be used to<br />

toggle between two outlines. For example, if an MVG is installed in a bus, when the bus is parked in the lot, the<br />

“Parked” outline – which activates sensors, notifications, and event-triggered recording – can be loaded. When the<br />

bus driver begins driving, he or she can flick the switch to load the “Driving” outline, in which sensors and most<br />

notifications are deactivated, and recording is continuous.<br />

NOTE:<br />

This feature can only be activated in the Sensor 1 configuration screen if it is first enabled in the<br />

General <strong>System</strong> Settings screen (see General <strong>System</strong> Settings, page 19).<br />

NOTE:<br />

In some cases, an alarm panel may be connected to In1 instead of a toggle switch. In this case, the<br />

alarm can perform the same function as the toggle switch –when the alarm is turned on or off, it<br />

automatically toggles the active outline as well. For additional information, please refer to the<br />

installation guide or consult your vendor.<br />

To configure Sensor 1 as an outline switch:<br />

1. In the Main Menu, under Sensors, click Sensor 1. The Sensor #1 configuration screen opens.<br />

Configuring Sensor and Activator Settings 115

Hooray! Your file is uploaded and ready to be published.