Defining Alternate Outlines<br />
Outlines define alternate sets of recording and event-handling settings. For example, for the MVG, you could define<br />
one set of settings for times when the vehicle is in operation and another set for when it is parked; when the vehicle<br />
is in operation, the motion and sensor notifications would be turned off, but when it is parked, they would be turned<br />
on.<br />
Outline configuration is an optional feature of the <strong>TVG</strong>. If you do not define any outlines, all the event-handling<br />
settings are automatically stored in the Default outline. You do not have to configure the outline settings at all in<br />
this case. If you choose to use the Outline feature, you can define up to five additional outlines.<br />
When multiple outlines have been defined, the running outline – the outline whose settings are currently being used<br />
by the system – can be switched in one of three ways:<br />
• Manually: By selecting the desired outline in the configuration utility, as described below<br />
• Sensor: In response to sensor events on Sensor 1 (toggling of a switch connected to In1)<br />
• Schedule: According to a predefined schedule<br />
The outline-switching alternatives are mutually exclusive; only one of the three switching methods can be active at<br />
any given time. The active outline-switching method is selected in the General <strong>System</strong>s Settings screen (see<br />
page 24). For information about using Sensor 1 to trigger outline switching, see Configuring Sensor and Activator<br />
Settings, page 110. For information about setting up a schedule for outline switching, see Schedules, page 73.<br />
NOTE:<br />
On CVG and CVG-M models, sensor-triggered outline switching should not be used if the sensor<br />
connector (In1) is used to control the display on a connected CCTV monitor. For additional<br />
information, see Configuring Sensor and Activator Settings, page 110; Configuring a Sensor to Control<br />
CCTV Display, page 116, and refer to the unit’s installation guide.<br />
The name of the outline that is currently running is displayed at the top of the screen.<br />
Running outline<br />
Figure 132: Outline that is currently running<br />
Creating an Outline<br />
In addition to the default outline, you can create up to five additional outlines.<br />
To create a new outline:<br />
1. In the Main Menu, click Outlines. The Show Outlines screen opens.<br />
Defining Alternate Outlines 118