OAJ “O’ZLITINEFTGAZ”<br />

ПТЭО «Комплексное обустройство<br />

месторождения Сургиль с извлечением ценных<br />

компонентов»<br />

The pump sends fuel oil fuel oil through a filter at the burner boilers pressure.<br />

Waste water discharged by gravity for the installation of waste water.<br />

Thus, the fuel system Akchalak MCC should utilize the most combustible waste<br />

processing units of the complex, contributes to a significant reduction in environmental<br />

pollution.<br />

11).<br />

To ensure trouble-free operation mode AGHK project provides flare system (Figure<br />

For the collector of wet jet separator installation ethylene connected devices,<br />

operating at temperatures above 0 ° C (absorber and desorber, quench tower, and<br />

depropanizer debutanizer, compressors and echo PRU).<br />

For the collector dry jet separator installation ethylene connected devices, operating<br />

at a temperature lower than 0 ° C (demetanizatory deetanizatory and install gas separation<br />

and the installation of ethylene, ethylene fractionation column, compressor PRU).<br />

By installing sewer jet separator of polyethylene connected devices installed<br />

polyethylene (separators, reactors, absorbers, adsorbers).<br />

By installing sewer jet separator butene-1 connected devices installed butene-1<br />

(reactor, distillation column, a column of butene-1, the capacity of the spent catalyst).<br />

All four flare separator summed fuel gas for purging. All four flare separator<br />

connected to the flare line to it is connected and storage products and fuel system is<br />

complex. According to the flare line discharges enter the trunk flare (flare pressure) by<br />

torchlight water seal (150 mm), which prevents the flow of air into the system of flare line.<br />

When the water seal is broken, evaporation, pass the molecular sieve and burned in the flare<br />

tip. To obtain the smokeless combustion of flare headroom injected steam.<br />

Provides periodic flare stack as necessary burning discharge and dispersion of<br />

combustion gases in the atmosphere.<br />

Torch carries the greatest load at full power outage or a complete cessation of the<br />

cooling water. Also at starting complex for the torch will be supplied substandard product.<br />

The torch burns as required periodic discharges, whose composition can vary within wide<br />

limits.<br />

Water from the jet drive is directed to the wastewater treatment plant.<br />

Книга 2. Часть 2. Проект ЗВОС по строительству ГХК<br />