“Management of Ustyurt GCC infrastructure objects<br />

and <strong>Surgil</strong> GCF construction” UE »<br />

unit (sprayer). 3 persons will be involved in suppression of sulfate reducing bacteria in cuttings storage<br />

barn (technologist, unit driver and operator), duration of operation is 1 day. Scope and types of<br />

works, and also required quantity of materials for suppression of sulfate reducing bacteria in cuttings<br />

storage barn are resulted in table 8.1.<br />

Table 8.1 – Required quantity of materials, scope and types of works for suppression of sulfate<br />

reducing bacteria<br />

№№ Parameter name Unit<br />

Numerical<br />

value<br />

1 2 3 4<br />

1.<br />

Drilling cuttings treatment (moving, semi-liquid, fluid<br />

phase)<br />

m 3 345<br />

2. Blue copperas (СuSO 4 )х5Н 2 О kg 34.5<br />

3. SAS kg 690<br />

4. Process water m 3 0.7<br />

5. Tank truck with tank capacity to 6m 3 pcs. 1<br />

6. Reagent preparation for work (mixing in tank truck) un. 1<br />

7.<br />

Drilling cuttings surface treatment by 10% blue copperas<br />

and SAS solution<br />

un. 1<br />

8. Set in operation labor content person 2<br />

9. Duration of operation day 1<br />

10. Tank truck transportation under own power<br />

8.6.16. After realization of measures for drilling cuttings neutralization from hydrogen sulfide, on<br />

the expiry of 2 days, there are begins works on drilling cuttings neutralization/hardening.<br />

Whereas that drilling cuttings contains oil products in small amounts, it is necessary to add<br />

to binding substance – Portland cement quicklime in quantity to 20% from cement. Also, for<br />

reduction of consumable it is allowed bentonite addition in drilling cuttings, concerning to<br />

IV danger class – low-hazard dangerous wastes. In the case of EСO-2hardener use there is<br />

not required consumables.<br />

8.6.17. This stage of neutralization/hardening of the upper, moving, fluid layer of drilling cuttings is<br />

carried out manually or mechanically, at contractor discretion, under condition of strict observance<br />

of labor safety rules and operational experience on drilling wastes disposal in cuttings<br />

storage barn in the Southwest Gissar and Kandym fields.<br />

8.6.18. With a glance of DSW clarification and time of drilling cuttings sludge for DSW evaporation,<br />

it is accepted, that before the beginning of works on drilling cuttings neutralization/hardening,<br />

the liquid phase practically is absent and there is to 40-50sm of semi-fluid<br />

paste-like phase on barn surface (calculations of thickness volume of evaporation of water<br />

are resulted in Appendix 3).<br />

8.6.19. Prior to the beginning of works there is carried out preliminary survey of the barn territories,<br />

one of the barn sides near which there is the plain and cleared area for engineering, is accepted<br />

for base and there is made hollows excavation by excavator from three opposite sides<br />

into the perimeter of barn (in 3-4 hollows from each side) for liquid phase leavings running<br />

off from lenses. All works on drilling cuttings mixing and cuttings storage barn alignment<br />

are executed from the base side.<br />