13.01.2015 Views

Surgil ESIA Report - Volume III - EKN

Surgil ESIA Report - Volume III - EKN

Surgil ESIA Report - Volume III - EKN

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

“O’ZLITINEFTGAZ” PC<br />

PFS “<strong>Surgil</strong> field complex costruction with valuable<br />

components retrieval”<br />

Ecological feature of Urga field regional location is its dislocation in deserted region<br />

characterized absence of industrial projects owing to the environment does not feel<br />

considerable man’s impact.<br />

One of the large objects affected formation of atmospheric background level in the<br />

considered territory is preliminary gas treatment plant (GSP) of Urga field in which structure<br />

there is the torch farm consisting of low and high pressure torches, intended for popping of<br />

weathering gases formed at technological process of gas and condensate treatment.<br />

Tank farm is the second by importance from the objects located in the given area,<br />

consisting of six tanks for gas condensate reception, measurement, storage and shipment.<br />

Sources of hydrocarbons emissions in atmosphere are six tanks; two pumps and gas<br />

condensate loading station in tank lorries.<br />

The ponds-evaporators located in close proximity to GSP are possible to characterize<br />

as object with rather insignificant hydrocarbons emissions in atmosphere.<br />

The boiler house of camp which working on natural gas concerns to additional<br />

pollution sources of atmosphere. There is emitted the insignificant amount of harmful<br />

substances in atmospheric air such as: nitrous dioxide and carbon oxide.<br />

Quality of atmospheric air is defined both amount and conditions of emissions, and<br />

scattering power of atmosphere.<br />

There have been carried out the early calculation of stray fields under operation of<br />

field for definition of existing situation of atmospheric air pollution, from which it is visible<br />

that emissions of the harmful substances of Urga GSP in atmosphere do not create a<br />

dangerous air gas content not by one of components of pollutants.<br />

The concentrations created by emissions of harmful substances in atmosphere on<br />

components are following:<br />

- carbon oxide - peak concentration in atmosphere have no exceeding of<br />

established norms in one of design point of the given area which values are<br />

less than 0.01 MPC;<br />

- hydrocarbons – peak concentration in atmosphere have no exceeding of<br />

established norms in one of design points of the given area which values<br />

does not exceed maximum-permissible norms of MPC;<br />

- nitrous dioxide – peak concentration in atmosphere have no exceeding of<br />

established norms in one of design points of the given area which value is<br />

0.12-0.04 of MPC;<br />

- nitrous oxide – peak concentration in atmosphere have no exceeding of<br />

established norms in one of design points of the given area which value<br />

does not exceed maximum-permissible norms of MPC.<br />

Thus, due to distance of <strong>Surgil</strong> GCF from sources on Urga field there not be felt te<br />

man’s impact.<br />

<strong>Volume</strong> 2. Part 1. EIS Project for <strong>Surgil</strong> field construction<br />

11