Settings and Configurationsd-<strong>lab.2</strong>, d-<strong>lab.2</strong>plus, net<strong>lab.2</strong>plus: Operation4.4.7.2 Setting the Temperatures and Calibrating the SensorsWARNING!The calibration of the sensors involves a safety risk, as the tank section of thePaper Processor must be opened while the machine is on (risk of electric shock ifliquids are spilled).Therefore we recommend to have the temperature adjustment and sensorcalibration made by a service technician.Call up: Press in this order:SettingsMachine settingsPP temperaturesThe screen Paper Processor temperaturesettings opens.014Setting the nominal values: Check the values entered in the buttonsDEV, BX, STB (developer, bleachfix,stabilizer) and Dryer one after the other,press the buttons, if necessary, and enter therespective nominal temperatures:DEV 40 °C ± 0.3BX 38 °C ± 3STB 37 °C ± 3Dryer 65 °C4-36 2005-05-01 / PN 04092_01 AgfaPhoto