12.07.2015 Views

d-lab.2, d-lab.2plus, netlab.2plus - D-Lab 1

d-lab.2, d-lab.2plus, netlab.2plus - D-Lab 1

d-lab.2, d-lab.2plus, netlab.2plus - D-Lab 1

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

d-<strong>lab.2</strong>, d-<strong>lab.2</strong>plus, net<strong>lab.2</strong>plus: OperationTestsFastMBL TestA FastMBL can be started as soon as the last print of a running order is in the PaperProcessor. Only one MBL test print will be printed and measured. A calculation andcorrection of the "Master Balance" is made if the measuring results are within a certainallowable deviation. There is no further print for checking, however, the result is added toall papers (unless in tolerance) just as in a "normal“ MBL.A message will be created if the results of the FastMBL are not within the expectedcorrection range. In this case the deviation is too high to get all measuring fields back intolerance with only one iteration process. In this case a "normal“ MBL must be printed toget the production back into a neutral range. Press in this order:TestStart FastMBL55.5 Calibrating the Scanner (Pixel Correction, PIKO)Applies only to d-<strong>lab.2</strong>/2plusThe pixel correction calibrates the light path of the lamp all the way to the CCD. It isrequired for the following jobs:– Balancing the pixel sensitivity of the CCD (for each single pixel).– Defining the illumination intensity (influenced by lamp, filter, mirror box, film carrier),e.g. in case of lamp replacement.– To define the window of the inserted film carrier (illumination on the CCD chip).The pixel sensitivity varies, among others, with the temperature of the CCD chip and withbrightness. For this reason, the PIKO is executed automatically in the following cases:– Machine startup(Whereby any film carrier may be inserted when the machine is started.)– Film carrier change– changing from negative film to slide and vice versa– Major light and temperature fluctuations (light path / CCD)Manual PIKO is only required if it was not terminated correctly. This may happen if therewere particles in the light path, e.g. paper , film, or the film carrier is not correctlyinserted.Starting the PIKO manuallyFilm carrier must be inserted and empty. Insert a film carrier (if not done before) andremove / eject film if necessary.AgfaPhoto 2005-05-01 / PN 04092_01 5-21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!