Maintenanced-<strong>lab.2</strong>, d-<strong>lab.2</strong>plus, net<strong>lab.2</strong>plus: Operation The lamp fitting (1) is kept in the holder bymagnets. Pull the lamp fitting (1) out of theholder and take out the old lamp with aclean cloth. Check the lamp socket (2):If the lamp socket or the contacts show anydiscoloring caused by heat, this indicatescontact problems that may have a negativeeffect on the print result. If necessary, havethe lamp socket replaced by a servicetechnician.dlabr072CAUTION!Do not touch the new lamp with bare hands. Finger prints reduce the service lifeof the lamp. Use the protective foil or a clean cloth. Insert the new lamp in the lamp fitting. Insert the lamp fitting (1) in the holder. Close the lamphouse cover.Resetting the counter for operating hoursNoteThe function is only accessible to users who have been given the Test rights.See User Manager: Defining Users and Assigning User Rights in Chapter 4.Call up: Press in this order:TestMaintenanceScanner lampThe counter for the operating hours is reset.0488-46 2005-05-01 / PN 04092_01 AgfaPhoto