Maintenanced-<strong>lab.2</strong>, d-<strong>lab.2</strong>plus, net<strong>lab.2</strong>plus: Operation8.3 Daily Maintenance8.3.1 Cleaning the APS Film CarrierApplies only to d-<strong>lab.2</strong>/2plusPurpose:Correct reading of magnetic data.Clean the magnetic head every day so that possible deposits cannot dry and make thecleaning more difficult.Material:cleaning strips and cleaning fluid– 3 cleaning strips (order no. CM+9.8506.1330.1)– Complete set:3 cleaning strips+100 ml Isopropanol bottle (empty)(order no. CM+9.8506.1320.1)– First filling by the service in the country– Refilling by the customer (without service).CAUTION!Clean the APS film carrier only with Isopropanol! Other cleaning agents willdamage the transport rollers TR4 / TR5 (rubber) and in addition they dissolve thebonding of the cleaning strips. Dissolved glue will dirty the magnetic headirreversibly.CAUTION!Isopropyl alcohol is a flammable liquid which may cause irritation of eyes and dryskin. After maintenance wash your hands with water.Isopropanol can damage the lacquer of the machine. Remove any splashesimmediately.8-8 2005-05-01 / PN 04092_01 AgfaPhoto