d-<strong>lab.2</strong>, d-<strong>lab.2</strong>plus, net<strong>lab.2</strong>plus: OperationMaintenance8.4.9 Cleaning the Filters in the ASTOR and Water InletsASTOR: AgfaPhoto Stabilizer Tank Overflow ReductionPurpose:To ensure optimum processing quality.11 ASTOR2 Water3 Water tank cover238dlab2513 Open the door right of the docking station(press the snap lock: middle left).The water tank cover (3) must be closed. Close the drain cocks of the three inlets. Unscrew the cap nuts (1, 2) and carefullyremove them: they are full of liquid. Remove the filters and rinse them in freshwater. Insert the filters again:do not mix up the ASTOR filter (1) with thewater filters (2)! Open the drain cocks again.NoteMake sure that the shut-off tap is tight on thehousing (may move up during turning). If thetap is not correctly mounted there is a risk ofstabilizer (STB) leaking from the Astor tank. Close the door.AgfaPhoto 2005-05-01 / PN 04092_01 8-35