Appendix H-Setting the <strong>RMX</strong> for Integration Into Microsoft OCS Environment<br />

H-22<br />

4 Make sure the IP Network Type is set to H.323 & SIP even though SIP<br />

will be the only call setup used with Office Communications Server<br />

2007.<br />

5 Make sure that the correct parameters are defined for the Signaling<br />

Host IP Address, MPM 1 IP Address, MPM 2 IP Address (if necessary),<br />

and Subnet Mask.<br />

Make sure that the IP address of the <strong>RMX</strong> Signaling Host is the same one<br />

defined as a trusted host in Office Communications Server 2007.<br />

6 Click the SIP Servers tab.<br />

7 Make sure the IP address of the Office Communications Server 2007<br />

is specified and the Server Domain Name is the same as defined in the<br />

OCS and in the Management Network for the DNS.<br />

8 Change the Transport Type to TLS.<br />

The Send Certificate button is enabled.