Configuration 2: R7r (+CMS) R7csi<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 2 Task— Assign Processor Channels<br />

This task associates data links (hardware) with processor channels (software) on<br />

Switch 2.<br />

Steps<br />

Begin<br />

> Open the Processor Channel Assignment <strong>for</strong>m — enter ch <strong>com</strong> p<br />

change <strong>com</strong>munications-interface processor-channels<br />

PROCESSOR CHANNEL ASSIGNMENT<br />

Page 1 of X<br />

Proc Gtwy Interface Destination Session Mach<br />

Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID<br />

1: y mis____ s 5_ 5001__ node-2____ 0____ 1 _ 1__ __<br />

2: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

3: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

4: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

:<br />

21: y dcs ___ c 5_ 0 node-1____ 5003_ 21_ 12_ 1_<br />

:<br />

64: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

> Enter values<br />

Field<br />

Conditions/Comments<br />

Processor Channel 1: (connection to CMS)<br />

Enable Set to y.<br />

Appl. Enter mis <strong>for</strong> the CMS connection on Processor Channel 1.<br />

Mode<br />

Set the Mode to s (“server”) on both switches <strong>for</strong> connections<br />

to CMS.<br />

Interface Link This must match the link number assigned on the node-5 data<br />

module screen on this switch.<br />

Interface Chan For TCP/IP, interface channel numbers are in the range 5000<br />

– 64500.<br />

The re<strong>com</strong>mended values are: 5001 <strong>for</strong> CMS, 5002 <strong>for</strong> Intuity<br />

AUDIX, and 5003 <strong>for</strong> DCS connections that are not gateways.<br />

These three values should be reused <strong>for</strong> multiple instances of<br />

these applications; <strong>for</strong> example, if there are two Intuity<br />

AUDIX’s, use 5002 <strong>for</strong> both; or if there are four DEFINITY<br />

<strong>ECS</strong>’s, use 5003 <strong>for</strong> all four. The <strong>com</strong>bination of Link,<br />

Interface Channel, and Mach ID must be unique.<br />

The re<strong>com</strong>mended values <strong>for</strong> gateway switches is 6001–6099.<br />

The interface channel number must be unique <strong>for</strong> each<br />

gateway.<br />

1 of 3<br />

90<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

CID: 77730 555-233-504 — Issue 1 — April 2000