E C-LAN Installation<br />

This chapter provides instructions <strong>for</strong> installing and making the physical connections to the circuit packs that are<br />

new <strong>for</strong> R7 — the C-LAN (TN799) and the NetPkt (TN794) circuit packs. The C-LAN circuit pack is optional<br />

<strong>for</strong> R7 but required <strong>for</strong> TCP/IP connectivity in all switch models. The NetPkt circuit pack is required <strong>for</strong> R7 in<br />

the si model only.<br />

These instructions are also included in the upgrades and installation documents <strong>for</strong> each switch model. They are<br />

duplicated here <strong>for</strong> convenience and <strong>com</strong>pleteness.<br />

Overview<br />

Systems in a DCS network are interconnected by both tie trunks (<strong>for</strong> voice<br />

<strong>com</strong>munications) and data links (<strong>for</strong> control and transparent feature in<strong>for</strong>mation).<br />

Various DS1 interface circuit packs (including TN464C, TN767C, TN722, and<br />

TN760) provide the voice-<strong>com</strong>munications interface. For TCP/IP connectivity, the<br />

data-link interface is provided by a TN799 C-LAN circuit pack.<br />

The C-LAN handles the data-link signaling in<strong>for</strong>mation in one of two configurations;<br />

either 10BaseT ethernet or point-to-point (ppp).<br />

• In the ethernet configuration, the C-LAN passes the signaling in<strong>for</strong>mation over a<br />

separate 10BaseT TCP/IP network, usually via a hub. For this configuration,<br />

install the C-LAN circuit pack and connect the appropriate pins of the C-LAN I/O<br />

field to the hub as described below.<br />

• In the ppp configuration, the C-LAN passes the data-link signaling to the DS1 <strong>for</strong><br />

inclusion in the same DS1 bit stream as the DCS voice transmissions. For this<br />

configuration, install the C-LAN circuit pack; no other connections are needed.<br />

In both configurations, the appropriate DS1 circuit packs must be installed if they are<br />

not already present.<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />