<strong>Network</strong>ing Screens<br />

A Screens Reference<br />

Destination Digits<br />

Used to enable access to the correct trunk group at the far end of the connection. This<br />

is typically the trunk access code (TAC) plus the extension of data module on the far<br />

end. If you use just the extension, then you must administer UDP and AAR route<br />

patterns to access the correct trunk group.<br />

Valid Value<br />

The extension or TAC<br />

+ extension of the<br />

destination data<br />

module.<br />

Usage<br />

If a trunk access code (TAC) is used, prepend the TAC<br />

to the extension.<br />

If the Establish Connection field is n, this field<br />

should be left blank.<br />

Destination Node Name<br />

Name of the node at the far end of this connection.<br />

Valid Value<br />

A name administered on<br />

the Node Names Screen.<br />

Usage<br />

Chap?<br />

Challenge Handshake Authentication Protocol.<br />

Valid Value<br />

y/n<br />

Usage<br />

Identifies whether the Challenge Handshake Authentication<br />

Protocol is used over this link. If you enter y, the system<br />

will prompt <strong>for</strong> a CHAP secret (password).<br />

Chap Secret<br />

Password <strong>for</strong> the Challenge Handshake Authentication Protocol.<br />

Valid Value<br />

1–30 alphanumeric<br />

characters, but<br />

cannot begin with<br />

the “at” sign (@).<br />

Default is blank.<br />

Usage<br />

This field displays only if the CHAP field is y. This field<br />

displays the data being entered or changed. It displays an<br />

asterisk (*) when the <strong>for</strong>m is brought up initially if the field<br />

already contains some data.<br />

This field displays the actual contents rather than asterisks if<br />

the <strong>for</strong>m is brought up by the init login.<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />