Configuration 1: R8r R8si<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 1 Task — Assign Processor Channels<br />

This task associates data links (hardware) with processor channels (software) on<br />

Switch 1 and specifies the destination node and machine ID.<br />

Steps<br />

Begin<br />

> Open the Processor Channel Assignment <strong>for</strong>m — enter ch <strong>com</strong> p<br />

change <strong>com</strong>munications-interface processor-channels<br />

PROCESSOR CHANNEL ASSIGNMENT<br />

Page 1 of X<br />

Proc Gtwy Interface Destination Session Mach<br />

Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID<br />

1: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

2: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

:<br />

12: y dcs ___ s 1_ 5003 node-2____ 0____ 12_ 21_ 2_<br />

:<br />

64: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

> Enter values <strong>for</strong> processor channel 12<br />

Field<br />

Conditions/Comments<br />

Enable Set to y.<br />

Appl.<br />

Set to dcs <strong>for</strong> DCS signaling.<br />

Mode<br />

node-1 is the "server" <strong>for</strong> this session. Set node-2 to "client"<br />

(c).<br />

Interface Link This must match the link number assigned on the node-1<br />

data module screen in the previous task.<br />

Interface Chan For TCP/IP, interface channel numbers are in the range 5000<br />

– 64500.<br />

The re<strong>com</strong>mended values are: 5001 <strong>for</strong> CMS, 5002 <strong>for</strong><br />

Intuity AUDIX, and 5003 <strong>for</strong> DCS connections that are not<br />

gateways. These three values should be reused <strong>for</strong> multiple<br />

instances of these applications; <strong>for</strong> example, if there are two<br />

Intuity AUDIX’s, use 5002 <strong>for</strong> both; or if there are four<br />

DEFINITY <strong>ECS</strong>’s, use 5003 <strong>for</strong> all four. The <strong>com</strong>bination<br />

of Link, Interface Channel, and Mach ID must be unique.<br />

The re<strong>com</strong>mended values <strong>for</strong> gateway switches is<br />

6001–6099. The interface channel number must be unique<br />

<strong>for</strong> each gateway.<br />

This number must match the Destination Port number on the<br />

node-2 Processor Channel screen.<br />

1 of 2<br />