Configuration 3: R8si R8r Gateway<br />

R8si<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 2 Task — Assign Link via procr-intf Data Module to Switch 1<br />

This task administers a processor-interface data module <strong>for</strong> the x.25 connection to<br />

node 1. The data module associates a link number with a physical channel number<br />

and extension number <strong>for</strong> the PI port used <strong>for</strong> this connection.<br />

Steps<br />

Begin<br />

> Open Data Module <strong>for</strong>m — enter a da n<br />

add data-module next<br />

Page 1 of 1<br />

DATA MODULE<br />

Data Extension: 4121<br />

Name: _x.25 on link 2 to node-1__<br />

Type: procr-intf COS: 1 Maintenance Extension: 4191<br />

Physical Channel: 02_ COR: 1 Destination Number: 8122102<br />

ITC: Restricted TN: 1 Establish Connection? n<br />

Link: 2_ DTE/DCE: dce Connected Data Module: _______<br />

Enable Link: n<br />

ABBREVIATED DIALING<br />

List1: _______________<br />

SPECIAL DIALING OPTION: ________________<br />

ASSIGNED MEMBER (Station with a data extension button <strong>for</strong> this data module)<br />

1.<br />

Ext<br />

Name<br />

> Enter values.<br />

Field<br />

Type:<br />

Physical Channel:<br />

ITC:<br />

Link:<br />

Name:<br />

COS:<br />

COR:<br />

TN:<br />

DTE/DCE:<br />

Conditions/Comments<br />

This indicates the data-module type <strong>for</strong> this<br />

connection.<br />

This must be the same as the link number.<br />

Enter restricted. (unrestricted is used only <strong>for</strong><br />

wideband transmission.)<br />

The link number must be in the range 1 –25 (<strong>for</strong><br />

R8si), not previously assigned on this switch.<br />

In<strong>for</strong>mation-only; appears in list generated by the “list<br />

data module” <strong>com</strong>mand.<br />

The values <strong>for</strong> these fields will be specified by the<br />

system administrator.<br />

The DTE/DCE assignments must be opposites on the<br />

two ends of the connection. Use dte <strong>for</strong> node 1.<br />

1 of 2<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />