H.323 Trunk <strong>Admin</strong>istration 2 H.323 Trunks<br />

Task 2 — Define IP Interfaces<br />

The IP interface <strong>for</strong> each C-LAN and MedPro board on the switch must be defined on<br />

the IP Interfaces <strong>for</strong>m. Each DEFINITY switch in an IP network has one IP Interfaces<br />

<strong>for</strong>m.<br />

Task 2 Steps<br />

Begin<br />

> Open IP Interfaces <strong>for</strong>m — enter ch ip-i<br />

change ip-interfaces Page 1 of 2<br />

IP Interfaces<br />

Inter-region IP connectivity allowed? n<br />

Enable<br />

Net<br />

Eth Pt Type Slot Code Sfx Node Name Subnet Mask Gateway Addr Rgn<br />

y C-LAN 01A10 TN799 B clan-a1 255.255.255.0 192.168.10 .100 1<br />

y MEDPRO 01A13 TN802 B medpro-a1 255.255.255.0 192.168.10 .100 1<br />

y MEDPRO 01A16 TN802 B medpro-a2 255.255.255.0 192.168.20 .100 1<br />

y C-LAN 01A09 TN799 B clan-a2 255.255.255.0 192.168.20 .100 2<br />

y MEDPRO 01B13 TN802 B medpro-a3 255.255.255.0 192.168.10 .100 2<br />

y MEDPRO 01B09 TN802 B medpro-b1 255.255.255.0 192.168.10 .100 2<br />

n 255.255.255.0 . . .<br />

> Enter values<br />

Field<br />

Inter-region IP<br />

connectivity<br />

allowed?<br />

Enable Eth Pt<br />

Type<br />

Slot<br />

Code<br />

Sfx<br />

Node name<br />

Conditions/Comments<br />

Enter y to allow IP endpoints (phones and trunks) to use<br />

MedPro resources administered in regions that are<br />

different from the endpoints’ regions.<br />

The Ethernet port must be enabled (y) be<strong>for</strong>e it can be<br />

used. The port must be disabled (n) be<strong>for</strong>e changes can be<br />

made to its attributes on this screen.<br />

Enter c-lan or medpro.<br />

Enter the slot location <strong>for</strong> the circuit pack.<br />

Display only. This field is automatically populated with<br />

TN799 <strong>for</strong> C-LAN or TN802 <strong>for</strong> MedPro.<br />

Display only. This field is automatically populated with B<br />

<strong>for</strong> the TN802 and TN799.<br />

Enter the unique node name <strong>for</strong> the IP interface. The node<br />

name entered here must already be administered on the<br />

Node Names screen<br />

1 of 2<br />

40<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />