<strong>Network</strong>ing Screens<br />

A Screens Reference<br />

Data Module Screens<br />

The Data Module screen must be administered at both ends of a DCS connection, except <strong>for</strong> ISDN connections.<br />

There are two types of data modules used with TCP/IP connections — ppp and ethernet. There are two types of<br />

data modules used with BX.25 connections — the proc-intf data module is used <strong>for</strong> the csi and si models, and the<br />

x.25 data module is used with the r model. The pdm data module is needed when the r model is connected to an si<br />

model via x.25.<br />

The fields that are <strong>com</strong>mon to two or more of the data module types are described first, followed by the screen<br />

pictures and descriptions of the fields that are unique <strong>for</strong> a given data module type.<br />

Common Data Module Fields<br />

The following fields are <strong>com</strong>mon to two or more of data module types.<br />

Data Extension<br />

Extension number <strong>for</strong> this data module.<br />

Valid Entries<br />

A 1- to 5-digit<br />

number consistent<br />

with the Dial Plan<br />

Data Module<br />

Types<br />

ppp<br />

ethernet<br />

procr-intf<br />

x.25<br />

pdm<br />

Usage<br />

The data extension is entered on the<br />

<strong>com</strong>mand line. If next is entered on the<br />

<strong>com</strong>mand instead of an extension<br />

number, the system assigns the next<br />

available extension number.<br />

Type<br />

The data module type, which determines the connection type.<br />

Valid Entries<br />

For TCP/IP connections:<br />

ppp and ethernet.<br />

For X.25 connections:<br />

proc-intf (<strong>for</strong> the csi and si<br />

models)<br />

x.25 and pdm (<strong>for</strong> the r-model).<br />

Data<br />

Module<br />

Types<br />

ppp<br />

ethernet<br />

procr-intf<br />

x.25<br />

pdm<br />

Usage<br />

Enter the data module type that<br />

is appropriate type <strong>for</strong> the<br />

connection type and switch<br />

model.<br />

For an r-model connected to an<br />

si-model via X.25, a pdm data<br />

module needs to be<br />

administered in addition to the<br />

x.25 data module.<br />

256<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />