DEFINITY Switch <strong>Connectivity</strong><br />

1 <strong>Network</strong>ing Overview<br />

For IP Trunk connections, the voice data is sent over IP facilities as RTP datagrams<br />

using the IP Interface assembly (TN802 or TN802B) — each packet can potentially<br />

take a different route through the network. The call and DCS signaling data are sent<br />

as datagram packets over an IP network using the C-LAN interface. The R7 type of IP<br />

trunk (IP Interface operating in ip trunk mode) can also use tie-trunk PVC facilities<br />

<strong>for</strong> the DCS signaling.<br />

Release 8 Hardware Requirements<br />

For the three DEFINITY <strong>ECS</strong> switch models — csi, si, and r — Release 8 IP trunking (H.323) and IP Softphone<br />

connections require at least one IP Interface (TN802B) circuit pack and at least one C-LAN (TN799B) circuit<br />

pack. DEFINITY One requires only the IP Interface circuit pack.<br />

IP Interface<br />

C-LAN<br />

The IP Interface assembly (J58890MA-1 L30) is a 3-slot wide TN802B circuit pack<br />

that provides voice processing over IP connections. The IP Interface assembly<br />

contains an NT processor, which is automatically administered by the DEFINITY<br />

software. The TN802B can be administered to operate in medpro mode <strong>for</strong> H.323<br />

trunks and IP softphones, or in ip trunk mode <strong>for</strong> R7-type IP Trunk connections.<br />

The C-LAN circuit pack, TN799B, provides call setup, TSCs, QSIG, and DCS<br />

signaling over IP connections.<br />

Note:<br />

The TN799B must be used to handle call signaling <strong>for</strong> the TN802B in<br />

MedPro mode. However, the previous version of C-LAN (TN799) can be<br />

used <strong>for</strong> call signaling with the TN802 or the TN802B operating in IP<br />

Trunk mode. The TN799 can also be used <strong>for</strong> DCS signaling connections<br />

on a switch that is using the TN802B in MedPro mode, as long as there<br />

are TN799Bs to handle the call signaling <strong>for</strong> the TN802B.<br />

Hardware Requirements <strong>for</strong> Upgrades from Pre-R7 Switches<br />

DEFINITY release 7 introduced several hardware changes that are also required <strong>for</strong> release 8. This section<br />

summarizes the hardware changes needed <strong>for</strong> pre-R7 switches upgrading to R8 <strong>for</strong> each switch model and each<br />

type of non-H.323 connectivity.<br />

R8r model<br />

The following table shows the hardware required <strong>for</strong> an upgrade to an R8r.<br />

Connection Type<br />

BX.25 (Existing<br />

systems only)<br />

TCP/IP<br />

(ethernet and ppp)<br />

ISDN-PRI<br />

Hardware Required<br />

PGATE (TN577)<br />

C-LAN (TN799B)<br />

No hardware changes required<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />