Configuration 5B: R8csi R8r (2 C-LANs)<br />

R8si<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 2 Task — Assign Link via ppp Data Module to Switch 1<br />

This task administers a ppp data module on Switch 2 <strong>for</strong> the ppp connection to Switch<br />

1. The data module associates a link number with a port address, extension number,<br />

and node name <strong>for</strong> the C-LAN port used <strong>for</strong> this connection.<br />

Steps<br />

Begin<br />

> Open Data Module <strong>for</strong>m — enter ad da 3020<br />

add data-module 3020<br />

DATA MODULE<br />

Page 1 of x<br />

Data Extension: 3020 Name: _ppp on link 1 to node-1a-ppp BCC: 2<br />

Type: ppp COS: 1<br />

Port: 01a0413 COR: 1<br />

Link: 1_ TN: 1<br />

Enable Link? n<br />

Node Name: node-2___ _<br />

Subnet Mask: 255.255.255.0<br />

Establish Connection: n<br />

DESTINATION<br />

Digits: __________<br />

Node Name: node-1a-ppp______<br />

CHAP? n<br />

> Enter values<br />

Field<br />

Type:<br />

Port:<br />

Link:<br />

Enable Link?<br />

Name:<br />

BCC:<br />

Conditions/Comments<br />

This indicates the data-module type <strong>for</strong> this connection.<br />

In this example, the C-LAN circuit pack is in slot 01a04; the ppp<br />

connection is through port 13.<br />

The link number must be in the range 1 – 25 (<strong>for</strong> R8csi), not<br />

previously assigned on this switch<br />

If you need to add an IP route that uses this node as a gateway,<br />

this field must be set to y be<strong>for</strong>e adding the IP route. Otherwise<br />

leave this field set to n until the link administration is <strong>com</strong>plete;<br />

that is, until after all data modules and the processor channels<br />

are assigned, then set to y.<br />

In<strong>for</strong>mation-only; appears in list generated by the “list data<br />

module” <strong>com</strong>mand.<br />

Bearer Capability Class. This is a display-only field.<br />

1 of 2<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />