Other <strong>Network</strong>ing-Related DEFINITY Screens<br />

A Screens Reference<br />

Primary<br />

Enter the 5-character circuit pack location number <strong>for</strong> the circuit pack that will<br />

function as the primary synchronization source. The clock circuit pack’s internal<br />

source is the implicit last choice. Only one switch in the network can function as the<br />

primary synchronization source. Only displays when the Stratum field is 4.<br />

The Primary and Secondary synchronization sources (DS1 or BRI trunk facilities)<br />

must be on the same Port Cabinet (that is, PPN, EPN1, or EPN3).<br />

Valid entries<br />

Usage<br />

01 through 44 (G3r) First and second characters are the cabinet number<br />

01 through 03 (G3si)<br />

A through E<br />

Third character is the carrier<br />

01 through 20 Fourth and fifth characters are the slot number<br />

blank<br />

A blank entry means no external source.<br />

Secondary<br />

The system will select automatically the secondary circuit pack if the primary circuit<br />

has a failure. Only displays when the Stratum field is 4.<br />

The Primary and Secondary synchronization sources (DS1 or BRI trunk facilities)<br />

must be on the same Port Cabinet (that is, PPN, EPN1, or EPN3).<br />

Valid entries<br />

Usage<br />

01 through 44 (G3r) First and second characters are the cabinet number<br />

01 through 03 (G3si)<br />

A through E<br />

Third character is the carrier<br />

01 through 20 Fourth and fifth characters are the slot number<br />

blank<br />

A blank entry means no external source.<br />

Pages 1–X of the screen<br />

Location/Name<br />

Identifies the location and name <strong>for</strong> each DS1 or BRI trunk circuit pack administered<br />

via the DS1 or BRI Trunk Circuit Pack screen. Only displays if the Stratum field is 4.<br />

Valid entries<br />

Display-only field.<br />

Usage<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />

305