Configuration 3: R8si R8r Gateway<br />

R8si<br />

3 C-LAN <strong>Admin</strong>istration<br />

> Submit the screen the screen<br />

End<br />

Field<br />

Destination Port<br />

Session - Local<br />

Session - Remote<br />

Mach ID<br />

Conditions/Comments<br />

The Destination Port number must match the Interface<br />

Channel number <strong>for</strong> this connection on the Switch-1<br />

Processor Channel screen.<br />

The Local and Remote Session numbers can be any value<br />

between 1 and 256 (si model) or 384 (r model), but they<br />

must be consistent between endpoints. For each<br />

connection, the Local Session number on this switch must<br />

equal the Remote Session number on the remote switch<br />

and vice versa.<br />

It is allowed, and sometimes convenient, to use the same<br />

number <strong>for</strong> the Local and Remote Session numbers. It is<br />

allowed, but not re<strong>com</strong>mended, to use the same Session<br />

numbers <strong>for</strong> two or more connections.<br />

Destination switch ID identified on the dial plan of the<br />

destination switch.<br />

Processor Channel 32: (connection to Switch 1 <strong>for</strong> gateway to Switch 2)<br />

Enable Set to y.<br />

Appl.<br />

Set to dcs <strong>for</strong> DCS signaling.<br />

Mode<br />

Node-3 is the “client” <strong>for</strong> this session. Set node-1 to<br />

“server” (s).<br />

Interface Link This must match the link number assigned on the node-3<br />

data module screen.<br />

Interface Chan A value of 0 allows any available interface channel to be<br />

used <strong>for</strong> this connection. This number must match the<br />

Destination Port number on the Switch-1 Processor<br />

Channel screen.<br />

Destination Node Name of the far-end node <strong>for</strong> this channel. This must be a<br />

name entered on the Node Names screen.<br />

Destination Port The Destination Port number must match the Interface<br />

Channel number <strong>for</strong> this connection on the Switch-1<br />

Processor Channel screen.<br />

Session - Local For each connection, the Local Session number on this<br />

switch must equal the Remote Session number on the<br />

Session - Remote<br />

remote switch and vice versa.<br />

Mach ID<br />

Destination switch ID identified on the dial plan of the<br />

destination switch.<br />

2 of 2<br />

122<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />