04.11.2014 Views

Definity ECS Admin for Network Connectivity.pdf - TextFiles.com

Definity ECS Admin for Network Connectivity.pdf - TextFiles.com

Definity ECS Admin for Network Connectivity.pdf - TextFiles.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

E C-LAN Installation<br />

Install the C-LAN Circuit Pack<br />

The following sections describe the steps <strong>for</strong> installing the C-LAN circuit pack.<br />

Insert C-LAN Circuit<br />

Packs<br />

TCP/IP connections (10BaseT ethernet or ppp) require a TN799 C-LAN circuit pack.<br />

Complete the following steps to install these circuit packs.<br />

1 Determine the carrier/slot assignments of the circuit packs to be added. Both<br />

types of circuit pack can go into any port slot with the following exceptions —<br />

The C-LAN circuit pack cannot be installed in the A carrier <strong>for</strong><br />

~ the r model<br />

~ a duplicated si model<br />

2 Insert the circuit packs into the slots specified in step 1. You do not need to power<br />

down the cabinet to install a C-LAN circuit pack.<br />

<strong>Admin</strong>ister the C-LAN<br />

Bus Bridge <strong>for</strong> csi<br />

models<br />

For the csi model only, <strong>com</strong>plete the following steps to administer the Bus Bridge <strong>for</strong><br />

the new C-LAN circuit pack.<br />

Note:<br />

If there are 2 C-LAN circuit packs installed in this csi switch, administer<br />

the Bus Bridge <strong>for</strong> only one of them.<br />

1 Enter change system-parameters maintenance.<br />

2 At the bottom of Page 2, enter y in the Packet Intf2 field.<br />

3 Enter the location of the C-LAN circuit pack in the Bus Bridge field (<strong>for</strong> example,<br />

01a08 <strong>for</strong> cabinet 1, carrier A, and slot 8).<br />

4 Enter the port bandwidths or use the defaults in the Pt0, Pt1, and Pt2 Inter-Board<br />

Link Timeslots fields.<br />

5 Submit the <strong>for</strong>m.<br />

6 Verify that the bus bridge LED is lit on the C-LAN circuit pack. This indicates<br />

that the packet bus is enabled.<br />

Test the Packet Bus<br />

and C-LAN Circuit<br />

Pack<br />

To test the packet bus and the TN799 C-LAN circuit pack, the cabinet needs a<br />

TN771D Maintenance/Test circuit pack.<br />

1 If there is no TN771D circuit pack in the cabinet, place one in a port slot.<br />

2 Enter test pkt port-network 1 long. For more in<strong>for</strong>mation about these tests,<br />

refer to the “test pkt <strong>com</strong>mand” section in the maintenance book.<br />

3 If the TN771D circuit pack was already in the cabinet, leave it there.<br />

4 If you added the TN771D circuit pack to the cabinet in order to test the TN799<br />

circuit pack, remove it from the cabinet.<br />

414<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

CID: 77730 555-233-504 — Issue 1 — April 2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!