<strong>Network</strong>ing Screens<br />

A Screens Reference<br />

When adding an access endpoint with the ITC administered as restricted, its<br />

associated port can be a channel from a DS1 circuit pack with Zero Code Suppression<br />

administered as zcs or b8zs.<br />

For an existing access endpoint, ITC can only be changed from restricted to<br />

unrestricted if its associated port is a channel of a DS1 circuit pack with its Zero Code<br />

Suppression field administered as b8zs. If the port is on a channel of a DS1 circuit<br />

pack with its Zero Code Suppression administered as zcs or b8zs, the end validation<br />

fails and the <strong>for</strong>m submission is rejected. Without this end validation, a user could<br />

administer an access endpoint as unrestricted when in fact it is restricted, that is its<br />

associated port is a member of a DS1 circuit pack that uses ZCS data transmission.<br />

Valid Entries<br />

restricted<br />

unrestricted<br />

Data<br />

Module<br />

Types<br />

procr-intf<br />

pdm<br />

netcon<br />

analog-dm<br />

Usage<br />

Use restricted except <strong>for</strong> wideband endpoints.<br />

For unrestricted, only unrestricted<br />

transmission facilities (b8zs and hdb3) will be<br />

used to <strong>com</strong>plete the call. An unrestricted<br />

facility is a transmission facility that does not<br />

en<strong>for</strong>ce 1’s density digital transmission (that is,<br />

digital in<strong>for</strong>mation is sent exactly as is).<br />

For restricted, either restricted (ami-zcs or<br />

ami-basic) or unrestricted transmission facilities<br />

is used to <strong>com</strong>plete the call. A restricted facility<br />

is a transmission facility that en<strong>for</strong>ces 1’s<br />

density digital transmission (that is, a sequence<br />

of eight digital zeros is converted to a sequence<br />

of seven zeros and a digital one) via zcs coding<br />

on DS1 circuit pack.<br />

DTE/DCE<br />

Designates the interface defined by this data module as data terminal equipment or<br />

data <strong>com</strong>munications equipment.<br />

Valid Entries<br />

dte/dce<br />

Data Module<br />

Types<br />

procr-intf<br />

x.25<br />

Usage<br />

The DTE/DCE assignments must be<br />

opposites on the two ends of the connection.<br />

Remote Loop-Around<br />

Test?<br />

Activates/deactivates remote loop-around testing.<br />

Valid Entries<br />

y/n<br />

Data Module<br />

Types<br />

procr-intf<br />

pdm<br />

Usage<br />

Set to n unless testing.<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />