04.11.2014 Views

Definity ECS Admin for Network Connectivity.pdf - TextFiles.com

Definity ECS Admin for Network Connectivity.pdf - TextFiles.com

Definity ECS Admin for Network Connectivity.pdf - TextFiles.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Network</strong>ing Screens<br />

A Screens Reference<br />

Appl.<br />

Identifies the switch application used on this link.<br />

Valid entries<br />

audix, dcs, fp-mwi, gateway,<br />

gtwy-tcp, mis, msaamwl,<br />

msaclk, msahlwc, msallwc,<br />

msamcs, qsig-mwi, and blank<br />

Usage<br />

The gateway application is used <strong>for</strong> conversion<br />

between ISDN and either TCP/IP or BX.25.<br />

The gtwy-tcp application is used <strong>for</strong><br />

conversion between BX.25 and TCP/IP.<br />

These application types are used on the<br />

gateway switch only.<br />

Gtwy To<br />

Used <strong>for</strong> gtwy-tcp applications only. Identifies the processor channel that this<br />

processor channel is serving as a gateway to.<br />

Valid entries<br />

1-128 (csi model)<br />

1-256 (si model)<br />

1-384 (r model)<br />

Usage<br />

Two processor channels on the gateway switch are needed<br />

to set up a gtwy-tcp gateway, which converts between<br />

X.25 and TCP/IP protocols. For each of the two gtwy-tcp<br />

processor channels, the Gtwy To field points to the other<br />

gtwy-tcp processor channel.<br />

For example, if processor channels 5 and 17 are used <strong>for</strong> a<br />

gtwy-tcp gateway, Gtwy To <strong>for</strong> processor channel 5<br />

would be set to 17 and Gtwy To <strong>for</strong> processor channel 17<br />

would be set to 5.<br />

Mode<br />

Identifies whether the IP session is passive (client) or active (server).<br />

Valid<br />

entries<br />

c (client)<br />

s (server)<br />

blank<br />

Usage<br />

This field must be blank if the type of interface link is x.25 (r model)<br />

or procr-intf (si model). This field cannot be blank if the type of<br />

interface link is ethernet or ppp.<br />

Set the Mode to s <strong>for</strong> ppp or ethernet connections to CMS. Set<br />

opposite values (cs) on the endpoints <strong>for</strong> ppp or ethernet<br />

connections between switches or between a switch and Intuity<br />

AUDIX.<br />

274<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

CID: 77730 555-233-504 — Issue 1 — April 2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!