Configuration 3: R8si R8r Gateway<br />

R8si<br />

3 C-LAN <strong>Admin</strong>istration<br />

Field<br />

Session - Local<br />

Session - Remote<br />

Mach ID<br />

Conditions/Comments<br />

The Local and Remote Session numbers can be any value<br />

between 1 and 256 (si model) or 384 (r model), but they must<br />

be consistent between endpoints. For each connection, the<br />

Local Session number on this switch must equal the Remote<br />

Session number on the remote switch and vice versa.<br />

It is allowed, and sometimes convenient, to use the same<br />

number <strong>for</strong> the Local and Remote Session numbers. It is<br />

allowed, but not re<strong>com</strong>mended, to use the same Session<br />

numbers <strong>for</strong> two or more connections.<br />

Destination switch ID identified on the dial plan of the<br />

destination switch.<br />

Processor Channel 23: (The X.25 side of the gateway)<br />

Enable Set to y.<br />

Appl.<br />

Use gtwy-tcp <strong>for</strong> conversion between X.25 and TCP/IP.<br />

Gateway To Indicates a software connection between processor channels<br />

23 and 32.<br />

Mode<br />

Used <strong>for</strong> TCP/IP connections only.<br />

Interface Link This must match the link number assigned on the x.25 data<br />

module screen.<br />

Interface Chan The interface channel number must be in the range 1 – 64 <strong>for</strong><br />

an X.25 link.<br />

Destination Node Used <strong>for</strong> TCP/IP connections only.<br />

Destination Port Used <strong>for</strong> TCP/IP connections only.<br />

Session - Local For each connection, the Local Session number on this switch<br />

Session - Remote<br />

must equal the Remote Session number on the remote switch<br />

and vice versa.<br />

Mach ID Leave blank <strong>for</strong> gtwy-tcp.<br />

Processor Channel 31: (ethernet connection to Switch 3)<br />

Enable Set to y.<br />

Appl.<br />

Set to dcs <strong>for</strong> DCS signaling.<br />

Mode<br />

Node-1 is the “server” <strong>for</strong> this session. Set node-3 to “client”<br />

(c).<br />

Interface Link This must match the link number assigned on the node-1 data<br />

module screen.<br />

2 of 4<br />

110<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

CID: 77730 555-233-504 — Issue 1 — April 2000