Configuration 4: R8csi R8si Gateway<br />

R8csi<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 1 Task — Assign Processor Channels<br />

This task associates data links (hardware) with processor channels (software) on the<br />

node 1 switch.<br />

Steps<br />

Begin<br />

> Open the Processor Channel Assignment <strong>for</strong>m — enter ch <strong>com</strong> p<br />

change <strong>com</strong>munications-interface processor-channels<br />

PROCESSOR CHANNEL ASSIGNMENT<br />

Page 1 of X<br />

Proc Gtwy Interface Destination Session Mach<br />

Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID<br />

1: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

2: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

:<br />

13: y dcs ___ s 1_ 5003_ node-3____ 0 13__ 31_ 3_<br />

14: y gateway s 1_ 6002_ node-3____ 0 14__ 32_ __<br />

:<br />

64: n _______ _ __ _____ __________ 0____ ___ ___ __<br />

> Enter values<br />

Field<br />

Conditions/Comments<br />

Processor Channel 13: (ppp connection to Switch 3)<br />

Enable Set to y.<br />

Appl. Set to dcs <strong>for</strong> DCS signaling.<br />

Mode Node-1 is the “server” <strong>for</strong> this session. Set node-3 to “client”<br />

(c).<br />

Interface Link This must match the link number assigned on the node-1 data<br />

module screen.<br />

Interface Chan For TCP/IP, interface channel numbers are in the range 5000 –<br />

64500.<br />

The re<strong>com</strong>mended values are: 5001 <strong>for</strong> CMS, 5002 <strong>for</strong> Intuity<br />

AUDIX, and 5003 <strong>for</strong> DCS connections that are not gateways.<br />

These three values should be reused <strong>for</strong> multiple instances of<br />

these applications; <strong>for</strong> example, if there are two Intuity<br />

AUDIX’s, use 5002 <strong>for</strong> both; or if there are four DEFINITY<br />

<strong>ECS</strong>’s, use 5003 <strong>for</strong> all four. The <strong>com</strong>bination of Link, Interface<br />

Channel, and Mach ID must be unique.<br />

This number must match the Destination Port number on the<br />

node-3 Processor Channel screen.<br />

1 of 3<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />