Configuration 2: R7r (+CMS) R7csi<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 1 Task — Assign Link via ethernet Data Module to the LAN<br />

This task administers an ethernet data module <strong>for</strong> the ethernet connection to the CMS<br />

adjunct and to Switch 2. The data module defines a network interface — it associates<br />

a link number with a port address and node name <strong>for</strong> the C-LAN port used <strong>for</strong> this<br />

connection.<br />

Steps<br />

Begin<br />

> Open Data Module <strong>for</strong>m — enter a da n<br />

add data-module next<br />

DATA MODULE<br />

Page 1 of X<br />

Data Extension: 2377 Name: ethernet on link 2<br />

Type: ethernet<br />

Port: 01c0817_<br />

Link: 2<br />

<strong>Network</strong> uses 1’s <strong>for</strong> broadcast addresses? y<br />

> Enter values<br />

Field<br />

Type:<br />

Port:<br />

Link:<br />

Name:<br />

<strong>Network</strong><br />

uses 1’s <strong>for</strong><br />

broadcast<br />

addresses?<br />

Conditions/Comments<br />

This indicates the data-module type <strong>for</strong> this link.<br />

Ethernet connections must be assigned to port 17 on the C-LAN<br />

circuit pack.<br />

The link number must be in the range 1 – 33 (<strong>for</strong> G3r), not<br />

previously assigned on this switch.<br />

This field is in<strong>for</strong>mation-only; it appears in lists generated by the<br />

“list data module” <strong>com</strong>mand.<br />

Leave the default (y) if the private network contains only<br />

DEFINITY switches and adjuncts. Set to n only if the network<br />

includes non-DEFINITY switches that use the 0’s method of<br />

<strong>for</strong>ming broadcast addresses. See Appendix A, “Data Module -<br />

type ethernet” <strong>for</strong> more in<strong>for</strong>mation about this field.<br />

> Submit the screen<br />

End<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />