Configuration 2: R7r (+CMS) R7csi<br />

3 C-LAN <strong>Admin</strong>istration<br />

> Submit the screen<br />

End<br />

Field<br />

Session - Local<br />

Session -<br />

Remote<br />

Mach ID<br />

Conditions/Comments<br />

The Local and Remote Session numbers can be any value<br />

between 1 and 256 (si model) or 384 (r model), but they must<br />

be consistent between endpoints. For each connection, the<br />

Local Session number on this switch must equal the Remote<br />

Session number on the remote switch and vice versa.<br />

It is allowed, and sometimes convenient, to use the same<br />

number <strong>for</strong> the Local and Remote Session numbers. It is<br />

allowed, but not re<strong>com</strong>mended, to use the same Session<br />

numbers <strong>for</strong> two or more connections.<br />

Destination switch ID. This is the Local Node Number on the<br />

dial plan of the destination switch.<br />

3 of 3<br />

Intuity System <strong>Admin</strong>istration<br />

Procedure Overview<br />

The following is a checklist of procedures that must be <strong>com</strong>pleted to administer a<br />

DEFINITY <strong>ECS</strong> with a TCP/IP connection to a Lucent Intuity system. The<br />

DEFINITY administration procedures are described in DEFINITY <strong>ECS</strong><br />

<strong>Admin</strong>istrator’s Guide, 555-233-502 and in previous sections of this chapter. The<br />

Intuity system administration procedures are describe following the checklist.<br />

For a <strong>com</strong>plete description of the administration procedures <strong>for</strong> connecting an Intuity<br />

system to a DEFINTIY <strong>ECS</strong>, see Intuity Messaging Solutions — Using a LAN to<br />

Integrate with DEFINTIY <strong>ECS</strong>, 585-313-602 <strong>for</strong> Intuity R4.4 or 585-313-604 <strong>for</strong><br />

Intuity R5.<br />

DEFINITY <strong>ECS</strong> administration<br />

The following procedures must be done on the host switch:<br />

• <strong>Admin</strong>ister the local node number in the dial plan.<br />

• <strong>Admin</strong>ister the Intuity system voice ports as stations, including Class of<br />

Restriction (COR) and Class of Service (COS).<br />

• If the switch is a csi model, assign the bus bridge.<br />

• Assign node names <strong>for</strong> the Intuity system and the switch.<br />

• <strong>Admin</strong>ister a hunt group, and add the Intuity system voice ports to that hunt<br />

group.<br />

• Add an ethernet data module.<br />

• <strong>Admin</strong>ister a processor channel <strong>for</strong> the link from the switch to the Intuity system.<br />

• Enable the link on the ethernet data module.<br />

• Set up a coverage path <strong>for</strong> access to the voice port hunt group.<br />

92<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />