Configuration 2: R7r (+CMS) R7csi<br />

3 C-LAN <strong>Admin</strong>istration<br />

Enable links and processor channels<br />

You must enable links and processor channels be<strong>for</strong>e the connections can be used.<br />

To enable a link, open its data module screen (ch da [ext]) and set the Enable<br />

Link? field to y.<br />

[note: to view a list of assigned data modules and their extensions, enter the “list<br />

data-module” <strong>com</strong>mand (l da)]<br />

To enable the processor channels, open the processor channel screen (ch <strong>com</strong> p)<br />

and set the Enable field to y <strong>for</strong> each assigned processor channel.<br />

Note: 1. You must disable a link or processor channel be<strong>for</strong>e you can change its<br />

parameters.<br />

Note: 2. The busy-out <strong>com</strong>mand overrules the data module Enable Link? field.<br />

Note: 3. On the C-LAN boards, low-level connectivity can remain intact when<br />

higher-level applications such as DCS are not functioning. For example,<br />

an external ping to a C-LAN’s ethernet port could be successful even<br />

when the board is busied-out. When debugging connectivity problems,<br />

pinging only checks low-level connectivity.<br />

98<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

CID: 77730 555-233-504 — Issue 1 — April 2000