Configuration 1: R8r R8si<br />

3 C-LAN <strong>Admin</strong>istration<br />

Switch 1 Task — Assign Link via ppp Data Module to Switch 2<br />

This task administers a ppp data module on Switch 1 <strong>for</strong> the ppp connection to Switch<br />

2. The data module defines a network interface — it associates a link number with a<br />

port address and node name <strong>for</strong> the C-LAN port on Switch 1. It also specifies the<br />

node name <strong>for</strong> the destination node, which is a C-LAN port on Switch 2.<br />

Steps<br />

Begin<br />

> Open Data Module <strong>for</strong>m — enter ad da n<br />

add data-module next<br />

DATA MODULE<br />

Page 1 of x<br />

Data Extension: 2010 Name: _ppp on link 1 to node-2___ BCC: 2<br />

Type: ppp COS: 1<br />

Port: 01b0115 COR: 1<br />

Link: 1_ TN: 1<br />

Enable Link? n<br />

Node Name: node-1 _____<br />

Subnet Mask: 255.255.255.0<br />

Establish Connection: y<br />

DESTINATION<br />

Digits: 6113020________<br />

Node Name: node-2_________<br />

CHAP? n<br />

[The system assigns the extension 2010 to this data module. Instead of n (next) in the<br />

<strong>com</strong>mand line, you could specify any unused extension in the dial plan.]<br />

> Enter values<br />

Field<br />

Type:<br />

Port:<br />

Link:<br />

Enable Link?<br />

Name:<br />

Conditions/Comments<br />

This indicates the data-module type <strong>for</strong> this connection (ppp).<br />

In this example, the C-LAN circuit pack is in slot 01b01; the ppp<br />

connection is through port 15.<br />

For G3r, the link number must be in the range 1 – 33, not<br />

previously assigned on this switch.<br />

If you need to add an IP route that uses this node as a gateway,<br />

this field must be set to y be<strong>for</strong>e adding the IP route. Otherwise<br />

leave this field set to n until the link administration is <strong>com</strong>plete;<br />

that is, until after all data modules and the processor channels are<br />

assigned, then set to y.<br />

In<strong>for</strong>mation-only; appears in list generated by the "list data<br />

module" <strong>com</strong>mand.<br />

1 of 2<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />