<strong>Network</strong>ing Screens<br />

A Screens Reference<br />

Node Name<br />

The node name <strong>for</strong> the interface (C-LAN port) defined by this data module.<br />

Valid Entries<br />

A name administered on the Node<br />

Names Screen.<br />

For a ppp data module, AUDIX<br />

and MSA names listed on page 1<br />

of the Node Names screen are not<br />

allowed in this field — only<br />

names listed on pages 2–6 of the<br />

Node Names screen are valid.<br />

Data<br />

Module<br />

Types<br />

ppp<br />

Usage<br />

This name is associated with<br />

an IP address of the port on the<br />

Node Names screen.<br />

Destination Number<br />

This field specifies the destination of the link.<br />

Valid<br />

Entries<br />

Extension<br />

number or<br />

TAC +<br />

extension<br />

number or<br />

eia or<br />

external<br />

Leave blank<br />

if Establish<br />

Connection?<br />

is set to n.<br />

Data<br />

Module<br />

Types<br />

procr-intf<br />

x.25<br />

Usage<br />

Used to enable access to the correct trunk group at the<br />

far end of the connection. This is typically the trunk<br />

access code (TAC) plus the extension of data module<br />

on the far end. If you use just the extension, then you<br />

must administer UDP and AAR route patterns to<br />

access the correct trunk group.<br />

If a trunk access code (TAC) is used, prepend the TAC<br />

to the extension.<br />

Enter eia (simplex system only) <strong>for</strong> ...<br />

The Link field must be set to 1 <strong>for</strong> eia.<br />

For the x.25 data module, to connect the Adjunct via<br />

the cable on the back of the PGATE circuit pack, enter<br />

external. If a value other than external is used, the<br />

associated X.25 data module must have a baud rate of<br />

switched.<br />

This field can be left blank assuming the other side<br />

will call it; however, it is preferable to put in the actual<br />

digits of the other side and set the Establish<br />

Connection field to n. This enables you to identify<br />

which X.25 data module on the remote switch is<br />

expected to call this data module.<br />

Used to enable access to the correct trunk group at the far end of the connection. This<br />

is typically the trunk access code (TAC) plus the extension of data module on the far<br />

end. If you use just the extension, then you must administer UDP and AAR route<br />

patterns to access the correct trunk group.<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />

259