<strong>Network</strong>ing Screens<br />

A Screens Reference<br />

Data Module - type X.25 (used <strong>for</strong> BX.25 connections with the r model)<br />

This <strong>for</strong>m applies only to the r model.<br />

DATA MODULE<br />

Page 1 of 2<br />

Data Extension: ____<br />

Name: ____________________<br />

Type: x.25<br />

Remote Loop-Around Test? n<br />

Port: __ COR: 1 Destination Number: ______<br />

Baud Rate: __________ TN: 1 Establish Connection? n<br />

Endpoint Type:_________<br />

Connected Data Module: ____<br />

Link: 1_ DTE/DCE: ___ Error Logging? _<br />

Enable Link? n<br />

Permanent Virtual Circuit? _<br />

Switched Virtual Circuit? _<br />

Highest PVC Logical Channel: __<br />

Common Fields<br />

See Common Data Module Fields (256) <strong>for</strong> descriptions of fields on this screen that<br />

are not listed below.<br />

Baud Rate<br />

Specifies the data transmission rate <strong>for</strong> this connection.<br />

Valid entries<br />

Usage<br />

9600, 19200, switched Set to 9600 <strong>for</strong> DCS connections to the si model, or to<br />

an r model with an external 9600 baud data line.<br />

Set to switched <strong>for</strong> r-to-r connections with<br />

<strong>com</strong>mon-channel signaling on DS1 trunks.<br />

Set to 9600 <strong>for</strong> connections to Intuity.<br />

Set to either 9600 or 19200 <strong>for</strong> CMS, depending on<br />

the physical connectivity.<br />

Endpoint Type<br />

Must be assigned as adjunct. An endpoint type is a type of packet switched data<br />

endpoint that uses X.25 call control procedures. The X.25 Endpoint connects to<br />

external ports on the PGATE board and to the TDM bus via a DS1 trunk. Ports<br />

connected to the adjunct endpoint can be either DTEs or DCEs.<br />

Valid entries Usage<br />

adjunct Set to adjunct <strong>for</strong> DCS, CMS, or Intuity AUDIX.<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

555-233-504 — Issue 1 — April 2000 CID: 77730<br />

269